Load friendly: Stable sine wave AC output via SPWM modulation
Supports a wide range of battery technology: GEL, AGM, Flooded, LFP and program.
Dual LFP battery activation method: PV&mains
Uninterrupted power supply: simultaneous connection to utility grid/generator and PV
Intelligent programming: the priority of the output from different energy sources can be set
High energy efficiency: up to 99.9% MPpT capture efficiency
Instant viewing of operation: the LCD panel displays data and settings ,while you can alsobe viewed using the app and webpage.
Power saving: power saving mode automatically reduces power consumption at zero-load
Efficient heat dissipation: via intelligent adjustable speed fans
Multiple safety protection functions: short circuit protection, overload protection, reversepolarity protection, and so on.
Model | HF2430S80-H | Adjustable | |
Battery Input | |||
Battery type | Sealed、FLood、GEL、LFP、Ternar y | √ | |
Rated Battery Input Voltage | 24V ( Minimum Startup Voltage 22V) | ||
Hybrid Charging Maximum Charging Current | 80A | √ | |
Battery Voltage Range | 20Vdc~33Vdc ± 0.3Vdc(Under voltage Warning/Shutdown Voltage/Over voltageWarning/Over voltage Recovery...) | √ | |
Solar Input | |||
Maximum PV Open-circuit Voltage | 500Vdc | ||
PV Working Voltage Range | 120-500Vdc | ||
MPPT Voltage Range | 120-450Vdc | ||
Maximum PV Input Current | 13A | ||
Maximum PV Input Power | 4000W | ||
Maximum PV Charging Current | 80A | √ | |
AC Input(generator/grid) | |||
Mains Maximum Charging Current | 80A | √ | |
Rated Input Voltage | 220/230Vac | ||
Input Voltage Range | UPS Mains Mode:(170Vac~280Vac)土2% APL Generator Mode:(90Vac-280Vac)±2% | √ | |
Frequency | 50Hz/ 60Hz (Automatic Detection) | ||
Mains Charging Efficiency | >95% | ||
Switch Time (bypass and inverter) | 10ms(Typical Value) | ||
Maximum Bypass Overload Current | 30A | ||
AC Output | |||
Output Voltage Waveform | Pure Sine Wave | ||
Rated Output Voltage (Vac) | 230Vac (200/208/220/240Vac) | √ | |
Rated Output Power (VA) | 3300 (2850/2950/3150/3000) | ||
Rated Output Power(W) | 3300 (2850/2950/3150/3000) | ||
Peak Power | 6000VA | ||
On-load Motor Capacity | 2HP | ||
Output Frequency Range(Hz) | 50Hz土0.3Hz/60Hz±0.3Hz | √ | |
Maximum Efficiency | >92% | ||
No-load Loss | Non Energy-saving Mode: ≤50W Energy-saving Mode:≤25W (Manual Setup) | ||
General | |||
Certificate | CE(IEC 62109-1) | ||
EMC Certification Level | EN61000, C2 | ||
Working Temperature Range | -10°C ~ 55°C | ||
Storage Temperature Range | -25°C ~ 60°C | ||
Humidity Range | 5% to 95%(Conformal Coating Protection) | ||
Dimensions | 378mm*280mm*103mm | ||
Weight (KG) | 7.4 |